Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

Skip to content

U.S. Marshals

Arlington, Virginia

Location

Arlington, Virginia

Client

Vornado / GSA / U.S. Marshals Service

Contract Value

$57,500,000

Square Feet

336,000

Year Completed

2016

Schedule

20 weeks

8 phases

Key Partners

  • Gensler
  • GHT

Project  Types

Government
Washington, DC

Overview

The U.S. Marshals Service (USMS) is a federal law enforcement agency within the U.S. Department of Justice and is the oldest American federal law enforcement agency.

 

HITT was responsible for the 15-floor fit-out and renovation of the USMS building, which includes a fitness center and locker rooms, conferencing and training center with Skyfold partitions, an executive floor with Dooge veneer paneling and private restrooms, and a 9,000-sf SCIF.

 

The scope also included renovations to the main lobby to include a new storefront system. The team furnished and installed physical site security countermeasures.

The upgraded infrastructure includes additional restrooms on the conference / training floor, unisex restrooms on every floor, and a 24/7 supplemental HVAC system throughout the building. The HVAC system includes a 150-ton chiller and BMS, and a 450-KVA backup generator. Because the chiller and generator were installed in the penthouse, this required coordination with  FAA for permitting due to proximity with Reagan National Airport.