Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

Skip to content

Capital Region Readiness Center (CRRC)—VAMC Martinsburg

Martinsburg, West Virginia

Location

Martinsburg, West Virginia

Client

U.S. Department of Veterans Affairs

Contract Value

$33,000,000

Square Feet

66,000

Year Completed

2010

Schedule

21 weeks, design
52 weeks, construction

Key Partners

  • Wisnewski Blair and Associates (now HGA)
  • BKM Mission Critical Facilities

Overview

The Capital Region Readiness Center (CRRC) is a design-build project consisting of a new 66,000-sf, standalone, Tier III data center on the Veterans Affairs Medical Center (VAMC) campus in Martinsburg. The project included a one-story tilt-wall concrete building with a center clerestory located on approximately 5.8 acres. The data center includes SCIF space and 10,000 sf of raised access floor designed at 150 watts / sf.

 

The project also included four 800-kVA and one 80-kVA UPS, which are supported by three 2.25-MW generators fed from two 20,000-gallon fuel tanks. 16 30-ton CRAC units serve the data center on a chilled water loop and three 20-ton CRAC units serve the UPS battery room. The chilled water system and the secondary chilled water pumps allow for an N+1 redundancy. Building systems are monitored by a building automation system (BAS).